Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

too much pressure in boiler goes to three bars ?

vokera mynute 20e. pressure goes to three bars and continues to rise when boiler is left on. I have bled the rads and this has made no difference. i have replaced a noisy acuator and problem is still there.
paul, October 2008
If boiler only increasing in pressure when heating is on then your expansion vessel is burst or needing recharged. If increase in pressure when boiler is off then filling loop passing.

Robert adam, October 2008
filling loop letting by ?

dave the rave, October 2008
Make sure the filling loop is off, and not letting by.

matt, October 2008