Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

my boiler is not cutting out and radiators very hot?

as above - vokera boiler
angela, October 2008
Or perhaps the DHW microswitch is stuck in the 'demand' position. To check see if the burners are modulated by turning the hot water temperature setting dial up and down, also if microswitch is faulty CH will stay on when in 'summer' mode. Hard to say more without the model.

c, October 2008
your boiler main thermostat is knackered causing the boiler overheat thermostat to operate.there are also other reasons which could cause this ie bypass radiator shut off/boiler bypass closed/ corrosion in main heat exchanger and radiators

stevie w, October 2008
link Click here to see other fixes for Vokera.