Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

my boiler is not cutting out and radiators very hot?

as above - vokera boiler
angela, October 2008
Or perhaps the DHW microswitch is stuck in the 'demand' position. To check see if the burners are modulated by turning the hot water temperature setting dial up and down, also if microswitch is faulty CH will stay on when in 'summer' mode. Hard to say more without the model.

c, October 2008
your boiler main thermostat is knackered causing the boiler overheat thermostat to operate.there are also other reasons which could cause this ie bypass radiator shut off/boiler bypass closed/ corrosion in main heat exchanger and radiators

stevie w, October 2008