Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

divert valve?

my hot water works and my heating works but they will not work together i have been told that it may be my divert valve. 1) where is the valve aprox? 2) dose this sound poss?
kelvin stallion, November 2008
Depends on system.

If combi no they will not work at the same time, this is nature of the beast m'afraid.

If this is a system boiler or heat-only boiler, you may have an S or a Y plan system. If you have an S plan ( 2x 2-port zone valves) you can only do heating OR hot water, with a Y-plan (1x 3-port valve that will go mid-position) then you can have both at once.

BunSlinger, November 2008
corse they wont , its a divertor right? its one or tother not both at same time

wrinkly joe, November 2008