Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    paul asked ... Hook timing Janome QC 6260?    |    David asked ... Beeper bust?    |    Click here to ask your question

Baxi Combi 105 HE Pressure Gauge Fault? Continued ?

Hi b, thanks for your response 'when you say the filling loop letting by' i have checked both taps and both are turned off (cold water inlet/heating return), could there be a fault with the cold water inlet? and if so, is this something that i'm going to have to get an engineer to come out and fix? Thanks Bekki :o)
Bekki, December 2008
if you disconnect the filling loop and the pressure still rises, then you have a problem with the plate heat exchanger. assuming you are topping it up to 1bar and the pressure rises when the boiler is not operating

Paul the gasman, December 2008