Cass asked ... Replacing full bulb housing unit in Neff oven?    |    Pádraig O Sabhain asked ... How to fix Kenwood Slimline Dishwasher KDW45X20 with a F1 Er?    |    keith asked ... How to reset after battery change?    |    Carol asked ... How to remove roller from lawnmower?    |    Ariana Orellana asked ... Code?    |    Click here to ask your question

how do i re-start my Velaire Myson Boiler?

My boiler ran out a few days ago, i had it re-filled however when i turn it on none of the radiators are heating up. Its making all the noises of working but nothing is happening. can you help? Is there a re-set switch ? and if so Where ?
Darran, December 2008
my boiler is a myson sfi and it wont start up the pump runs butit wont fire is there anythink i can do

shane, January 2009
is there a reset button

shane, January 2009
forgot to say, remove front panel and you'll see a red button on the front of the pump, press this to get things going.

Bear, December 2008
I have the same problem with the same boiler. I'm told that there may be a blockage in the filter and/or pipe, as the crud from the bottom of the tank would have been stirred up when filled from empty. Also the 'nozzle' probably needs changing. Found the following from another website which i'm gonna try.....

If you have sludge in the filter, AND you have had your boiler serviced annually, get someone else to service it. If your service guy (assuming you had one) is OFTEC registered, OFTEC would be pleased to hear from you, and they will then inspect his work. Tank and filter checks are on the list of service items.

Once you have cleaned the strainers at the tank end, Turn off the oil at the boiler, and put a shallow tray under the burner. Switch off the power to the boiler, and unplug the cable that goes to the burner. Disconnect the pipe that goes into the pump, normally a 15mm spanner. Put the end of the pipe into a pot and open the oil valve. Run a couple of litres into a container. It should flow freely. Turn off the valve and reconnect the pipe, plug in the burner, turn on the power and try the burner.

Wipe the pipe joint with a piece of paper towel and check in about 15 mins for leaks.

If the oil didn't flow freely you need to find a way of pushing the oil back up the pipe to dislodge debris that is probably blocking the pipe.

Bear, December 2008