narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

24 CDI Water Problem?

I have a 24 CDI. The hot water is only running luke warm. I have taken off the microswitch on the diverter valve and switched it manually, the boiler fires up as it should and the temp dial is set to max. The heating seems to be working normally Ie. rads are hot.
I think the diverter diaphragm needs replacing also as it is not consistent lately, could it be linked?
Thanks in advance.
Leigh, January 2009
this sounds like the diaphragm this job can turn into a nightmare as the whole boiler is held together with o rings and even with an o ring kit which is essential the boiler still leaks good luck

jason, January 2009
Thanks Lee,
In that case, I'll try the diaphragm first and if it's no better, a valve.

Leigh, January 2009
yes poss diaphragm problem, but could also be diverter valve internals are letting-by water down the heating not giving 100% to hot water.

lee, January 2009