andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

boiler keeps shutting down?

the boiler keeps shutting down. the number 60 flashes. sometimes it will go for days without breaking down, other times its every couple of minutes. Please can you advise as to what the problem is.
(chaffoteaux & maury britony combi SE )
steve shaw, February 2009
Fault code 60 ( as long as that is the only led that is flashing ) is an ionisation pcb fault. PCB's are available from several sources - internet or local heating engineers... but it might be worth checking the ionisation electrode ( flame detector ) first. This is in the bottom left-hand side of the burner compartment, just above the burners... if it is damaged it can create strange symptoms.

J.R. Copley, May 2009
sounds like the pcb board

kev, February 2009