Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

my buderus combi needs topping up every 15 mins. I've bled the rads?

my boiler constantly needs refilling
kev, February 2009
if your loosing pressure its very likley your loosing water.
check your radiators for leaks and all your pipework.
check your pressure relief pipe which normally discharges outside. if that is leaking you will need a pressure relief valve.
you will need to make sure your boiler is not over pressurising (3 bar on gauge)
if you have experienced a loss of pressure a few times and then increased pressure (excessive) your expansion vessel is likley to be faulty .

tech boiler svs, February 2009