Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Boiler Excessive Pressure?

Ravenheat boiler keeps building up pressure, after reducing it down to 1bar each time.
RSD, February 2009
depending on waht model it could be may things
1. air pressure vessel at the back of boiler is empty of air, so when your heating warms up water expands and pressure increase.
2.if you have a secoundary water to water heat exchanger mains pressure water could be passing through this filling up your c/heating system slowly, this could also apply if you have a dual main heat exchanger. (see manefactures booklet for which)

liam, February 2009