Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

glo worm fuelsaver mk2 pilot keeps going off?

if i leave it on constant or even timed the pilot sometimes keeps going off leaving me with no heating. could it be the electronic ignition malfunctioning?

its had numerous thermocouples but dont think its ever had a replacement ignition. its serviced and repaired by british gas but i cant see how they have overlooked this.
robbie, February 2009
If its had thermocouples fitted then it cant be the fan assisted model.I agree with the first post in that it is likely to be the overheat stat or gasvalve.As for British Gas,do me a favour they dont strip them down anymore like we used to,they just bung in the old performance tester probe and thats it.Have you noticed their adverts state a safety check now and not a service.

Tony S, February 2009
where would the overheat stat be situated?

robbie, February 2009
If it has electronic ignition, it does not have a pilot. thats the point of electronic ignition, you do not need to burn gas by having a pilot on. If on the other hand, it does not fire up, when reqd. See above

Sheepdog, February 2009
its either a faulty gas valve or more likely a faulty overheat stat

mike, February 2009