Remove all power to the SCR Reciever, (No Lights showing), remove the batteries from the room unit, it is best to unscrew the room unit from the wall and take it to the Reciever. Re-apply power to the Reciever, press button 1 & 2 as per the instruction sheet. insert the Right hand set of batteries into the room unit in your hand, followed by the left set, after a short while the red light which as been flashing slowly should go out, the Green light will come on only if the flame symbol is showing on the room unit screen,
if the unit still fails to operate you will have to repalce the system you must repalce both parts as they are coded to only work as a matched pair, to get the heating on permanenty you can try pressing the override button on the reciever, the green light should come on and the heating should run, pressing O.ride again cancels operation hope this helps
Boiler Repairman - Ipswich, April 2009