Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

Hot water but no heating, pressure is v.low, how do I fix?

The boiler pressure reading is close to zero and I have no heating in all of my rooms except the one nearest to the boiler. Is it a simple matter of re-pressurizing the boiler and if so how is it done?
Scott C, January 2006
Repressurize your boiler via filling loop, a flexible silver hose usually situated on pipework close to boiler. Top it up to approx 1.5 bar and vent radiators. Pressure will drop slightly, so top up again to 1.5 bar when cold.

Joe, January 2006