Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Click here to ask your question

Hot water but no heating, pressure is v.low, how do I fix?

The boiler pressure reading is close to zero and I have no heating in all of my rooms except the one nearest to the boiler. Is it a simple matter of re-pressurizing the boiler and if so how is it done?
Scott C, January 2006
Repressurize your boiler via filling loop, a flexible silver hose usually situated on pipework close to boiler. Top it up to approx 1.5 bar and vent radiators. Pressure will drop slightly, so top up again to 1.5 bar when cold.

Joe, January 2006