andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Halstead Quattro Gold Combi Boiler?

I have just purchased a house that is fitted with a Halstead Quattro Gold Combi / Boiler .... There are no instructions with it. Does anyone know the safe working pressure (in BAR) I need to set this to?
Dave C, June 2009
With the Boiler Cold, you should fill the system using the filling loop to 1-00 Bar. once this pressure is reached be sure to turn off the filling loop securely.

You will notice that when the system heats up, the pressure will rise to anything up to 2-00 Bar, this is normal.

One more point to remember, if you bleed any of the Radiators, you will need to re-pressurise the system using the above method.

Hope this helps

www.elanar.co.uk, June 2009