Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

Request connection details of the Siemens central heating controller RWB2E?

Can any one supply wiring and connection details of the Siemens controller RWB2E central heating controller. What voltages should be on the outputs?
Thanks.
Mike, June 2009
There's a compatibility chart on page 2 of this PDF...

http://www.heatweb.com/pdf/Invensys/Programmer%20Compatibility%20Chary.pdf

It does not mention Siemens RWB2E but does show a Landis & Staefa RWB2E which I believe equals Siemens. It shows..

N = Neutral
L = Live
1 = H/W off
2 = C/H off
3 = H/W on
4 = C/H on

I would expect the voltage to be either 0V or 230V (in the UK) depending what the programmer is calling for.

Good luck...

Peccavi, June 2009