GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Central heating coming on when heating the water?

Hello,

We had an issue with the boiler a while back, it broke down and wasn't heating the water, bloke came and fixed it but now everytime we have the water on the heating (ie radiators) come on full whack - the thermostat is turned right down, and we have a panel below the boiler that you can use to turn the water on and off, and it also has a button for the radiators, this is turned off, yet, they ALL come on.

I've tried turning all the knobs on the radiators that have them to jus turn them down, but they come on regardless. With the weather lately, and the fact we have a full 8-9 hours of blazing sun coming into our flat, it's like torture being in here cos it just won't cool down properly.

It's a Maxol Microturbo 40H boiler, the panel underneath is a Danfoss CP15, and the hot water storage tank is a Systemate SP 144.

Any help or advice greatly appreciated, it feels like you're being cooked alive at times.
Claire, July 2009
i would think it is your 3-port valve has stuck,it is send ing heated water into your radiator system.it should have a manual slide/switch.try moving it ,these often stick

john, July 2009
diverter valve is passing (when you got the boiler on to heat up your hot water, the valve is not closing off properly on the heating side, which allows the radiators to come on)

STUBOW, July 2009