3 hours ago Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

potterton envoy 40?

please could someone help me...i have a potterton envoy 40 condensing boiler....the boiler only runs for about 30 mins or 2hrs if i'm lucky...then up comes the flashing E error then i have to reset the boiler 5/6 times aday...last year it had a new gas valve ( which broke the bank ) when i first had this fault it said replace the controller thinking they meant the control board which i replaced ( costing an arm & leg ) it lasted afew days and the fault came back....after blowing £500 altogether i'm back where i started thank u for any help
peter chipchase, February 2006
Fan Failure.
Undo the three wingnuts holding the fan to the bottom of the combustion chamber, take off the electrical connection and white air hose, drop the fan housng and clean it out.
You can blow it with an air line, and if possible add some light oil to lubricate the shaft.
e-mail me on tremar@tinyworld.co.uk for further advice.

Ray Milner, December 2008