Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Click here to ask your question

potterton envoy 40?

please could someone help me...i have a potterton envoy 40 condensing boiler....the boiler only runs for about 30 mins or 2hrs if i'm lucky...then up comes the flashing E error then i have to reset the boiler 5/6 times aday...last year it had a new gas valve ( which broke the bank ) when i first had this fault it said replace the controller thinking they meant the control board which i replaced ( costing an arm & leg ) it lasted afew days and the fault came back....after blowing £500 altogether i'm back where i started thank u for any help
peter chipchase, February 2006
Fan Failure.
Undo the three wingnuts holding the fan to the bottom of the combustion chamber, take off the electrical connection and white air hose, drop the fan housng and clean it out.
You can blow it with an air line, and if possible add some light oil to lubricate the shaft.
e-mail me on tremar@tinyworld.co.uk for further advice.

Ray Milner, December 2008
my boiler haas a number 9 flashing do u no what this means?

anthony singh, April 2008