3 hours ago Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Click here to ask your question

How do i set up a gas valve on a worcester R35 HE combi?

Recently purchased a worcester R35 HE plus combi gas valve as old one was passing gas. Instruction manual gone, anyone talk me thru set up of new valve?
Mark, August 2009
its ok, managed it..... called worcester themselves and was told 9.2% CO2 high rate, 8.8% low rate..... and quite easy to set up.... a lot easier than the greenstar, by that i mean not as sensitive. the levels can be attained easier.

cheers anyway

mark, August 2009
look up the instructions on the worcester website
http://www.worcester-bosch.co.uk/installer/literature/discontinued-boiler-literature/discontinued-gas-boiler-literature

Ian, August 2009
Sorry steve, didn't mention that i am actually a qualified heating engineer. I replaced a valve on a worcester greenstar 30CDI combi few weeks ago, very irritating job and that was with the manual. Very delicate set up with flue analyser and gauge etc. This is an earlier model and set up is obviously different, do not have manual. Anyone set one up before? If not, i'll just get worcester in to do the job.... but would appreciate feedback first

Mark, August 2009
Not to be funny Mark but get a qualified Gas Safe plumber in if any thing goes wrong YOU could end up in jail, best of luck.

Steve, August 2009