Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Click here to ask your question

I have a main medway boiler?

when I turn on hot water tap the boiler makes a loud bang and the pilot light goes out.
alan mills, August 2009
You don't want to mess with this yourself as it sounds like a stuck gas valve, which means the gas is remaining on after the water differential valve shuts off. This will activate the overheat and shut down the pilot via the thermo-electric valve. My best advise would to turn it off, don't use it and contact a Gas Safe Registered engineer.