Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

I have an overflow problem which has not been resolved by differnt plumbers?

Ball valve has been changed and the iron bend but still overflow problem continues.Last engineer suggested to have a look at cylinder thermostat/boiler thermostat as the o/flow water was initially warm and then becomes cold.When water is used in the bathroom the overflow stops.My boiler is Vokera.The hot water cylinder and cold water tank are in the same place in the loft.Please help as this is driving me crazy
dots, August 2009
It is Possible that the Coil in your HW Cylinder has failed, causing water to migrate from the large Header tank to the smaller F&E tank causing the overflow from the F&E Tank, Make sure that the ball-Vlave is not dripping into the F&E Tank first, otherwise new Cylinder

www.elanar.co.uk, August 2009
link Click here to see other fixes for Vokera.