Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Click here to ask your question

swiftflow glowworm 80 pressure?

does anyone know the correct pressure the combi should be at in standby mode and in heating mode cheers..
rob wilson, August 2009
thankyou thats a massive help...AJM..

R WILSON, August 2009
Hi
The system pressure should be 1 bar to 1.2 bar cold ie heating off, when heating is turned on the pressure will rise slightly perhaps to 1.5 to 1.8 bar but shouldn't really go past 2 bar, if it does your expansion vessel rear of boiler will want represurizing as over time the diaphram deflates.

AJM, August 2009