Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Mike asked ... Bosch WTA74200GB Vented Dryer?    |    Stuart G asked ... C3 Front Wiper control problem?    |    Clare S asked ... Repair Electriq dehumidifier?    |    Click here to ask your question

Repressuring Potterton Promax Boiler?

How often should you need to repressure a potterton promax he boiler. Does 2 or 3 times a year seem too much?
Jack, September 2009
Thanks for that Toke

Jack, September 2009
yerrrr by far probly once every 12 months unless you bleed some radiators..have you noticed the presure relief pipe outside leaking water? fil the boiler to 1 bar..put on the heating and watch the presure gauge if it rises towards 3 bar wen in use the expansion vessels probly gone flat and then the water is released throught the presure valve to outside..wen the boiler cools down ure left with no water.. all it needs is to be re inflated with a foot pump..otherwise..youve got a leak on the sytem..same again fill the system t 1 bar..close the flow and return valve under boiler and leave over nite..if the presures ok then youve got a leak on the system..second option probly unlikely as you would have noticed if you had a leak that big!! hope it helps m8

toke, September 2009