4 hours ago Steve asked ... Gilera runner 180 vxr 2001 ignition replacement?    |    Janboy68 asked ... How can I mend my KitchenAid Artisan toaster?    |    rick asked ... How can I fix my portable Zenith DVP615 DVD player? When I p?    |    Jim asked ... How can I get my scarifier to work?    |    george crawford asked ... Citroen C3 Picasso?    |    Click here to ask your question

Vokera linea 28 excessive water pressure build up when central heating?

When the central heating temperature is switched up high ie 55 degrees+ the water pressure climbs to 3 bar or more. What could be the cause of this? How difficult/ expensive to fix it?
Thank you
Peter E, November 2009
had the same problem check the braded pipe from the expansion vessel might be blocked

or the Flow Diaphragm got a split in it if its dropping down and you are gettin the 40 code hope this helps

Ice-Man, December 2009
:-)

ste, November 2009
thats what i said

b, November 2009
however if the pressure vessel not working you will need a replacement and could be a bit more expensive to replace get a professional in

max, November 2009
pressure on the expansion vessel needs checking
or expansion vessel may need replacing

b, November 2009