GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Ferroli Optimax HE 31 C, how do I put water pressure up?

Boiler is 4 weeks old and the water pressure is too low and I now have no heating. Does anyone have any idea how to up the water pressure? Tried all the knobs underneath the boiler and checked the instruction manual which is extremelly unclear. Help!!!
Jacqui, December 2009
Hi the black inlet knob is solid and will not turn so unable to screw it. Just had boiler engineer in charged a fortune and he has left it this tight whereas previously when water pressure was a problem we just unscrewed it. Don't ever think to buy this Ferroli it has given us hell and we have spent a fortune, should have replaced it and its only three years old. Whoever designed this needs.... thank you for any suggestions on undoing this black knob, hugely appreciated as no hot water or heating.

Patrick, December 2016
Hi I have done all this and now all I'm getting is 2 lines help

julie, February 2016
my cold water flow limiter has sprung aleak a air line crack in the black pastic cover are the parts on the shelve or have i got to get ferroli out to look at it

jocky1, November 2013
When I open the black valves water leaks out the one an the water pressure doesn't go up any help would be great thanks

Cally, February 2013
Thanks guys, saved me from freezing tonight - manual is absolute garbage

R Clark, February 2013
Problem solved, i now have heating.

Thank you so much for your answer!!

Chris, February 2012
ive tried all this and it seems one of the valves is broken, any idea what to do from here as my landlord is useless

kelly, October 2011
help need to get the pressure back up on my boiler

emma, March 2011
Hi M C did you get it sorted? im having the same problem, ive tried both black knobs and there's no water coming out. I'm desperate to get it back on, really grateful to any replies

Rich, January 2011
Same problem, manual useless, thank goodness for this site.

Tmh, January 2011
same problem, thanks Jim what u said fixed it. I found locating the black valve really hard as i thought a valve was like the blue one next to it- not a round thing. Now it is saying D2 but when i put the temperature up it seem to be fine again. Dundee in January, not the best time for a boiler break down. manual was hopeless.

Rob01542, January 2011
Just faced this problem myself. This is how to do it.

Turn the boiler OFF at the mains switch.
The only valves that need to be touched are the black ones.
Open one fully and start to unscrew the second.
You will hear a hiss. This is the sytem filling. Speed of fill depends on how far you open the valve. Takes a minute or less. Watch the guage under the right front and turn off at 1.5 bar.

Turn both black valves to OFF and switch the boiler back on. Check the pressure after a while to make sure its stable. Job done.

Jim, January 2011
Hi guys - so glad to have found this!

I tried doing the above and the gauge didn't even flinch and I was concerned to leave it open for so long. I bled a radiator last night (which had a lot of air in it) and therefore the pressure has gone.

How long do you usually have to keep the valve open for? Are we talking seconds or minutes?

Thanks guys

Mike Useless with Boliers Price, October 2010
Just found this reply on Google and it's sorted my problem out so thank you very much. The screen on the front told me I had a F37 problem and the manual told me what I needed to do (fill the system) but gave me no idea how to do that! Thank you very, very much! :-)

Terri, April 2010
Thank you - saved me from a very cold night!! Agree - manual as much use as a chocolate teapot.

Robin Hilton, January 2010
The only valves you touch when topping up with water are the black ones. firstly turn the one at the front half a turn then other half a turn you will hear the system fill up. check the valve and turn of when it gets to 1.5 bar then close the other black valve.

raymienets, January 2010
Look under the boiler on the right hand side and there is a water pressure dial. Just under that is a black valve. Open the valve until the pressure goes up to between 1 and 1.5 and then close the valve. The boiler should reset itself after a couple of minutes.

Bazza, December 2009
Having the same trouble myself. Tried the 2 blue taps, but there's no water coming out. Instruction manual is useless.

M C, December 2009