Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

24i/28i Junior Problem?

Father christmas has brought me an early present! Please help if you can! My boiler knocked off while in use and I got the slow red light flashing. When I try to reset the boiler mostly it doesn't work. I have got it to restart a couple of times, using only the reset procedure but it only works for approx five mins before knocking off again. It does not seem to be an increase or decrease in demand which knocks the boiler off i.e turning on or off hot water taps/radiators/shower. Just knocks off after a few mins. Mains water and Gas feed ok. Spark ok. If anyone has any ideas I would love to hear from you, many thanks...
Dale., December 2009
get your gas man to check the minimum burner pressure, it's set at next to nothing when i comes out of the factory, best to set it to around 2 mbar.

Ian, December 2009
brand new boilers come with least a 12/24 months warranty, so whoever fitted it, needs to come back and fix it .



"or your going to have a
very cold Christmas"

wirecutterman, December 2009
link Click here to see other fixes for Worcester Bosch 24i/28i Junior.