2 hours ago Dot asked ... Russell hobbs?    |    Jon asked ... How do I remove the flywheel. Mountfield 1640h ride on mower?    |    Keith Mumby asked ... Fordson starter solenoid?    |    Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Click here to ask your question

High Pressure?

Hi,
I have a Alpha 240E combimax boiler. The boiler pressure remains very high (around 4) despite draining water out of the radiator. Pleases advise what to do.
Kucchi, December 2009
the filler loop maybe letting past allowing more water into the system if possible get filler loop ends disconnected release excess pressure out through a rad bleed valve until about 1 to 1.5 bar pressure try it if pressure now climbs up boiler needs a look at by a professional

wirecutterman, December 2009