GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Worcester Bosch Greenstar 24i No Hot Water?

Hot water has stopped working.
Heating works fine.
Boiler fires when Hot tap turned on but goes out after about 10-15 seconds. No fault lights appear.
I've taken the front cover off to check for flue problem and it runs exactly the same, i.e. burner lights initially and then stops.
I've also checked and the condenser pipe is clear of ice.
Ideas please.
Paul, January 2010
Fixed!!!
Thanks Wayne.
I noticed that the pressure in the CH loop increased when the hot tap was on so seemed to me the diverter must be stuck.
I gave the diverter valve a donk with a hammer (very technical) and hey presto hot water.
I'd been away for 4 weeks so it must have stuck in position.
Thanks again

Paul, January 2010
Hello again Wayne.

Just thinking that as the water is running through the HW tap as fast as normal how would it not be going through the Heat Exchanger quickly enough?

Also could the diverter be stuck and the very hot water from the CH be getting in to hot water system and causing shut down?

Also surprised that no fault lights come on!

Paul, January 2010
Thanks Wayne.

Is there a way to check this as opposed to just changing the part?

Paul, January 2010
hi it sounds like your domistic heat exchanger the water is not getting through it quick enough to heat up then the boiler detects this and shuts the bioiler s down to save damage, if it runs fine on heating then that where your problems lies

wayne the plumb, January 2010
link Click here to see other fixes for Worcester Greenstar.