andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

top up with water?

valiant combi 2003, how do i top up with water
bill lavers, January 2010
look under bottom of the boiler for the filling loop, a silver braided pipe with taps mounted on either ends or quick turn screwdriver slots. Turn both taps ON 90 degree's watch the gauge do not let go past 1.5 bar on the gauge turn OFF BOTH TAPS
Note
some installers remove both the pipe and tap heads

wirecutterman, January 2010