No lights mean No power. You could have a short circuit somewhere that burnt your power supply. You may have a bad connection- check wire/ connector from main - be careful of high voltage.
Make sure the controller Voltage & case colour is the same as the previous. F&P uses colour to 'fool' proof mismatch between model.
Fault 130 means RPS error signal. Check for corrosion on the connector of the Rotor Position Sensor and the Motor Controller module connector.
2) Check the contacts on the rotor positional sensor harness to see if any have been damaged. (Each set of contacts in the socket has two wipers. If the distance between these wipers varies between different contacts, replace the rotor positional sensor harness or repair connector but remember that visual check is not good enough because they carries small signal to e processor > 1000 rpm and subjected to vibration).
If good, Replace Rotor Position Sensor.
If Fault persist, replace Motor Controller module.
Once job done, you need to run the dianogistic and set the size before you ^x#)(!# yet another M/Controller again.
cheers.
Pppp, January 2010