GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Thorn apollo 15/30B boiler?

I have a problem that the boiler runs ok with the burner cover off, but with it on the gas valve turns off after a few secons and if only the piolt is on then this will remain on for a few mintes the again turns off the gas valve. I have changed the thermocouple, linked out the over temp stat, Looking at the electrical wiring diagram i cannot see that it is anything electrical. therefore I am now puzzled. Can anyone please help. the snow is returning and I have no heating.
Austen, January 2010
hi i have apollo 15/30 the pilot is working but no burner mean no gas coming out please give me the advice that what do i have to do thanks

Khan, October 2010
Balance flue appliance check the heat exchanger is clean and check air inlet is clear and assembled either come apart or corroded

a, January 2010
Its an air pressure problem. you may need to clean the fan impellor, also check your flue is clear.

henry, January 2010
link Click here to see other fixes for Thorn.