Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Click here to ask your question

glow worn boiler says f9 on display and will not work?

glow worm combi boiler cxi not working says f9 on display tried the reset option doesnt work .
jac, March 2010
water pressure may be too low, try topping up. water pressure switch may be blocked, also on some early models the overheat stat, which has a manual re-set causes the same fault.

Ian, March 2010
F9 - Pressure -

water pressure connector loose/ unconnected/ faulty or wires trapped.
water pressure sensor faulty.
pump ceased/ faulty

http://www.glow-worm.co.uk/products/pdf/current/Ultracom_cxi_installation_manual.pdf

- page 46

hope this helps

Gaz, March 2010