Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

Damaged diaphragms on diverter valve assy Baxi 105E?

What is ideal regulated water pressure to Cold water inlet valve?. I am considering fitting Water Pressure Regulater upstream Water Inlet Valve to protect repeated diaphragm failure due to our high water supply pressure approx 3 1/2 Bar .
Thom Hall, March 2010
Thanks Ian. Have decided to fit two new replacement diapragms each time a service is due and inspect for wear.As you say fitting a reg may not be the answer.

Thom Hall, March 2010
around 3 bar should be ok for the cold supply. might be best to fit a mini expansion vessel on the pipe after the pressure reducing valve to prevent the pressure from climbing after a hot water demand.

Ian, March 2010