Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Damaged diaphragms on diverter valve assy Baxi 105E?

What is ideal regulated water pressure to Cold water inlet valve?. I am considering fitting Water Pressure Regulater upstream Water Inlet Valve to protect repeated diaphragm failure due to our high water supply pressure approx 3 1/2 Bar .
Thom Hall, March 2010
Thanks Ian. Have decided to fit two new replacement diapragms each time a service is due and inspect for wear.As you say fitting a reg may not be the answer.

Thom Hall, March 2010
around 3 bar should be ok for the cold supply. might be best to fit a mini expansion vessel on the pipe after the pressure reducing valve to prevent the pressure from climbing after a hot water demand.

Ian, March 2010