GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Damaged diaphragms on diverter valve assy Baxi 105E?

What is ideal regulated water pressure to Cold water inlet valve?. I am considering fitting Water Pressure Regulater upstream Water Inlet Valve to protect repeated diaphragm failure due to our high water supply pressure approx 3 1/2 Bar .
Thom Hall, March 2010
Thanks Ian. Have decided to fit two new replacement diapragms each time a service is due and inspect for wear.As you say fitting a reg may not be the answer.

Thom Hall, March 2010
around 3 bar should be ok for the cold supply. might be best to fit a mini expansion vessel on the pipe after the pressure reducing valve to prevent the pressure from climbing after a hot water demand.

Ian, March 2010