GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

what is wrong when F5 error shows? on ferroli boiler?

When the boiler is on there is an f5 error flashing up
delwina, March 2010
Flue fan or air pressure switch faulty

Mr fix it, November 2012
air pressure problems try to push air to the air pressure switch located on the uper right corner and then try to run the boiler again

ronen, January 2012
take fuse out of the electric box,put fuse back in and seems to reset itself,no more f5 faults!

wayne, September 2011
hi delwina i have the same problem if you have ficed your boiler is it possible you could give me an answer please?

andrew c, January 2011
The water pressure measurement unit is broken. Replace it with a new one. it's located in the middle, left and screwed in the water tube. Furthermore it's connected with a 3-pins connector. Replacement part does not need to be genuine and costs about 80 Euro.

Milan, September 2010
problem with ventilator - check ventilator and/or cables

DR, March 2010
link Click here to see other fixes for Ferroli.