tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    mike asked ... Fisher & Paykel 913t dishwasher?    |    Emma asked ... Foot pedal smoking?    |    Click here to ask your question

vokera pilotlight on pressure ok but no output fan seems to be running cons?

excel 80 sp no hot water or heating pilot on pressure 3 bar fan seems to be running all the time
denise, March 2010
fan should run all the time on this boiler.
low speed when no demand, high speed when water or heating on.
could be any number of faults, first things to suspect though would be flow switch diaphragm and high limit stat.
p.s. the pressure is too high at 3 bar

Ian, March 2010
link Click here to see other fixes for Vokera Excel 80 SP.