Don asked ... Find the charger or how to convert the battery?    |    Tanzania asked ... How can i mend my sanyo fwbp505f q?    |    Mark Goodwin asked ... Mount field 725m ride on mower?    |    Joan Sorrentino asked ... Barcalounger issue?    |    David asked ... Not starting until I bang door closed?    |    Click here to ask your question

baxi 105e?

I keep getting a flame failure neon light flashing and boiler shuts down until I reset it does anybody know whats wrong pls
dave, July 2010
when the PCB goes the fault shows up as fan fault, with no power to the fan.
I would check the sparking probes are clean all three

erj, July 2010
thanks for the answer erj i was wondering if the pcb had failed or something else

dave, July 2010
you need a gas safe eng for this one as you have to go into the burner.

erj, July 2010
link Click here to see other fixes for Baxi 105e.