andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Ravenheat boiler not staying lite?

I have a Ravenheat CSI Primary A condensing boiler it goes through the start proccess main burner comes in for 5-6 seconds then the boiler switchs off I have replaced the overheat stat and the airflow switch but the boiler is still the same.
Jeff Hilditch, July 2010
Flame rectification.

Check for decent earth connection to the boiler and correct polarity between L & N.
Check lead for ignition/rectification in good condition and not 'trapped'.
Also check the condense waste system is clear.

Carefree, July 2010