GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Ravenheat boiler not staying lite?

I have a Ravenheat CSI Primary A condensing boiler it goes through the start proccess main burner comes in for 5-6 seconds then the boiler switchs off I have replaced the overheat stat and the airflow switch but the boiler is still the same.
Jeff Hilditch, July 2010
Flame rectification.

Check for decent earth connection to the boiler and correct polarity between L & N.
Check lead for ignition/rectification in good condition and not 'trapped'.
Also check the condense waste system is clear.

Carefree, July 2010