Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

ive got no hot water on my combi, can u help?

ive got heating but no hot water on a glow worm swift flow 100 sit, do u know what the possible faults may be?
jon, September 2010
sorry, I got mixed up on the side of the boiler. Left hand side of the boiler as looking from the front, just above the mini expansion vessel. There is also a filter in the pipework make sure this is clean also.

corgigasman, September 2010
sounds like flow valve fault, not sensing water flowing through boiler. Flow valve located on pipe on the r/h side of the boiler. Usually starts by rattling first before failing alltogether.

corgigasman, September 2010