Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Replacing Pressure Gauge on WB Greenstar 28i?

I've just had a repair and service done on my Woster bosch greenstar 28i and every thing is now working ok. Appart from pressure guage is no longer working. I questioned the engineer just as he was leaving and he made out he hadn't noticed but evey thing was fine and he must of caught and nipped the pipe by accident and he would return and fit a new manometer in the next week. Maybe I shouldn't have paid him the full amount but i suspect he's not going to come back to fix it.
My question is if he doesn't show can I buy a replacement (£20 ebay) and swap it over myself. I'm assuming you have to drain and refill the system. Is this something I could do myself. How would i go about this.
ANON1, September 2010
hi,
you don't need to drain down full heating. look under boiler and there will be 2 slotted valves quarter turn. (make sure they are the heating flow & return) they will be marked the 2 outside ones out of the 5 pipes. then its just a split pin & pull gauge out of housing & replace.
piece of cake!!!

super mario, September 2010
link Click here to see other fixes for Bosch Greenstar.