Bob asked ... Charger fault?    |    Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    Click here to ask your question

Boiler going on/off independently of timer & no heating?

I have a Vaillant Combi-boiler VCW-GB 242E. It is continually switching on & off heating the water to boiling point, it seems, even when the timer is either off or on timed. We have no heating at all.
Linda Amos, October 2010
Most likely problem is the water section has leaked through the stuffing box, this 'gums' up the push rod above which (sounds like) is sticking the servo valve in the H/W demand position, this would indicate what you describe.

Solution: Replace the water section/stuffing box, clean the push rod above it, grease and replace. You will need to push the servo valve to one side to access the push rod.

Carefree, October 2010