Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Jerry asked ... Alpine 7287?    |    Guy asked ... Gaggenau fridge alarm problem?    |    Click here to ask your question

i need to adjust pressure on mynute 14-48 se boiler where is the pressure v?

i need to adjust the pressure on my mynutr 14-48 se boiler where do i have a pressure valve
judith paterson, October 2010
The filling loop will be an external loop between the cold water feed and CH (usually return), there will be two valves (possibly connected by a silver braided hosepipe).
There will be either screw slots or 1/4 turn taps (depending on make of loop), open these slowly, and watch the pressure rise to about 1 bar on the boiler guage (bottom left of the boiler).

Carefree, October 2010