GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

boiler water pressure goes down?

on my baxi combo boiler the water pressure keeps going down whithin 2/3 hrs it is empty some times 3/4 days sometimes 3/4 weeks
just noticed that when the heating is on its better
-is it time for a new one-
paddy, October 2010
hi with the radiators on from starting point the pressure should be 1 to 1,5 bar when cold with your heating on look at the pressure gauge does it go up into 2.5 to 3.0 bar quickly then blow the water off outside via the 15m copper blow of pipe if so the problem lies with your expansion vessel if without you using your central heating the pressure is still dropping then you have a leak on your central heating pipework have you recently had a carpet fitted or banged in a protruding nails in your floorboards which could have nicked a pipe universalheatingsparesuk

byron universalheatingsparesuk, October 2010
you have a leak, look for any wet spots around visible pipework, radiators and around the pressure relief pipe.

Ian, October 2010