1 hour ago mike asked ... F+p 913t dishwasher?    |    Emma asked ... Foot pedal smoking?    |    Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Click here to ask your question

Vokera Mynute 12-48 burner not firing?

Working on a Vokera Mynute 12-48 that won't light when there is demand for heat. Have replaced thermostat but still nothing. Have gone thru sequence of start up. There's 240 volts at flow switch and fan resistor (240v left side 180v on the right) but seems there's no voltage at terminal 3 or 1 on air pressure switch. Is this because the pump isn't turning over the flow switch to provide 240v to the air pressure switch and in turn not energising the gas valve? or could there be a deeper problem connected to pcb, solenoid or something?
Johnny Bhoy, October 2010
check the limit stats to the right of the pump

Ian, October 2010
link Click here to see other fixes for Vokera Mynute 12-48.