narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

how do i fill my boiler with water?

My valliant fan assisted condenser boiler is showing as 0.4 bar in the manual it says fill with water but i am not sure how to do this
Tina, November 2010
Well tina you could look in the book, but on the vaillant there are 2 grey valves underneath on on each side with a short grey wire flexible hose between the 2 open 1 of the small grey valves fully then open the other one a little bit and you will hear water going in, you should also see the gauge start to rise, let it come up to 1.5 bar or the middle of the green section on the small dial on the front right, then close both valves

alex, November 2010
some have a built in tap underneath others require a filling loop

ck, November 2010