2 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

pressure is only 0.8 bar?

two radiators down stairs are cold up stairs are fine, pressure is only 0.8 should be around 1.5 to 2.0 how do i increase pressure,
allen, November 2010
0-8 is still ok it is more likely the rads are airlocked turn off rads that are working this should do the trick some boilers have a built in refill otherwise look under the boiler for a flexible silver pipe at one or both ends there will be a tap with either a small black handle or a slot for a screwdriver do not turn anything with a blue red or yellow handle these are the boiler isolation valves

brian, November 2010