i have an ariston miro genus 23mffi combi bolier, when the boiler lights the electronic ignition still trys to spark & after about 15 seconds it cuts out, i've already had the detection electrode changed on the burners but the fault is still there.
i have ariston miro 28 it cuts out and a red light comes on when the boiler is hot. how can i resolve this problem?
jim, November 2008
Hi
If your boiler is continuing to spark and the burners are all completely lit and you have changed the detection electrode it has to be the pcb....i m positive im an ariston engineer!
IAN DITCHBURN, August 2006
Check that the electrode is correctly sited in the flame, you may also like to change the electrode wire (Very rare) or the rectification feature of the boiler's PCB is failed and a new PCB will be required...
CONTACT A CORGI REGISTERED ENGINEER TO EXCHANGE THE PCB AS IT MUST BE SETUP CORRECTLY FOR THIS APPLIANCE.