Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

greenstar worcester boiler not working?

Hot water is OK - no flashing red or blue light - no gurgling - condenser pipe lagged. Press the "chimney sweep" button and it works for 10 mins and then stops - any ideas
Johnny, December 2010
If the HW is okay, I'd suggest an external controls fault ie: clock/room thermostat.

The sweep button is for setting the boiler up in terms of CO2 ratios etc.

Carefree, December 2010
check the condensate trap/container - will need to take casing off the boiler, and the trap is lower left.

is it full? is so, remove and clean out the blockage (black sand-like deposits usually), then re-fit.

CMac, December 2010
link Click here to see other fixes for Worcester.