4 hours ago Jo asked ... How to engage clutch on old sewing machine to engage needle?    |    Jacky asked ... Miele Vacuum cleaner?    |    Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Click here to ask your question

Emptied condenser syphon on Greenstar 24i but still not working ?

I have cleared the condenser pipe on the above but boiler will still not fire up, there was water in the boiler casing & keeps going to 'lock out' - any ideas please ??
Robert Godsell, December 2010
I have just re-read your question saying that you have cleared the syphon, 'the water in the boiler casing' might be your issue now.
If you have a 'Prettle' gas valve (the connections are on the back of the valve), the lower connection could be sat in the water, this will also cause lockout.
You will need to dry thoroughly (I use a hairdryer in such cases) to completely disperse the lying water.

Carefree, December 2010
Try the actual condense trap inside the boiler, on the greenstar, they tend to block with a grey sand (from when the main heat exchanger was cast), clear this out, and hopefully, you'll be sorted.

Carefree, December 2010