GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

myson apollo 30/50b?

hi i wondered if any one can help after having to fit a new thermo coupling to my myson apollo 30/50b it made a banging noise like air trapped in the pipes? and it has then blown the new thermo coupling why ? thats 2 T/Cs in 2 months?
marks, January 2011
I a similar problem, a small clunk, then a rush of bubbles surging thru' the system and finally a massive banging noise, like someone hitting a radiator with a hammer. Pump overrun stat, goes in the back towards the bottom on the right onto a pipe coming off the heat exchanger. You need to take off the upper, outer cowelling, then the inner cover to get at it, costs about £15.00. Just unscrew old overrun stat and replace, only a few wires. Make a note of existing set-up or take a photo for reference if you really need to but it is very, very simple and obvious once you get the covers off.

DainO, November 2012
thanks for your quick reply will look into both as they are both getting on i years

marks, January 2011
you can't blow a t/c most likely cause is pump or divertor/zone valves faulty causing overheat stat to trip this disables the t/couple once they have tripped they can become tempremental

brian, January 2011
link Click here to see other fixes for Myson.