Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Click here to ask your question

Ravenheat boiler. Hot water not working and red light flashing?

Have a primary condensing boiler. Red light on front is flashing and the fan and pump are running. Hot water does not work and would welcome ideas to rectify.
bibi, May 2011
when i put hot water tap on after 20 second red light comes on and flames goes off

akmol, August 2011
what model ravenheat boiler is it?

does CH work?

if fan & pump work
can you hear it sparking?

need more information to properly diagnose problem

on most ravenheat boilers
the problems tend to be:-

CH & DHW thermistors
air pressure switch
ignition control board
ignition lead attached to condensate trap

i would need to eliminate these first to find out cause of problem

manwithnoname, May 2011
link Click here to see other fixes for Ravenheat.