Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

My Grant Euroflame boiler will not start?

Am I correct in saying that the burner starts first then after a few seconds the boiler comes on?
the burner starts up fine and will keep running even though the boiler has not started.
The problems Ive had before were always with the burner eg. faulty capacitor etc
Ive never had this problem before with the boiler not coming on
Gary, September 2006
it sounds like the burner is running without a flame.
this could either the photocell or control box.

s.ashdown, October 2006
air pressure switch poss faulty .fan on 1st,then air pressure switch then ignition then gas.all combis same procedure.try making air pressure switch by sucking / blowing down tubes to switch.

paul, October 2006
link Click here to see other fixes for Grant Euroflame.