narnia asked ... Matsui ct-111ss?    |    Jason asked ... How to fix handset problems ( intercom ) and access control?    |    andy asked ... Samsung VP-D60 camcorder?    |    Shopper asked ... Poor Renault Radio Reception?    |    reg bardle asked ... Lg 7kg dd?    |    Click here to ask your question

Biasi 24se, fires up, stops?

Biasi 24se, it fires up then locks after a short time.
Push reset, then boiler does same thing.
Have just changed the DHW pressure switch and gland.
Don, October 2011
Ok you haven't come back. I guess you haven't got a diagram so here is one possibility.
When your boiler fires up the flue gas fan starts, a differential pressure switch then closes if the fan is working properly.
It is not uncommon for the tubes which connect to the pressure switch to get clogged. This will give the sympton which you are experiencing.
Or the switch could be faulty.
You can test it by disconnecting the tube and gently blowing to operate the switch.
Alternatively it may be the fan which is not running at all.
So does the fan run then cutout.....ie fan ok
Check pressure switch.

ian, October 2011
Job for an electrical engineer.
Could be a number of things.
If you could post the wiring diagram I could give you ome suggestions.

ian, October 2011